Beli panel kontrol di monotaro.id
Kami Menampilkan Rekomendasi Kami Untuk Anda! Anda Bisa Membelinya Kapan Saja di monotaro.id
- Mitsubishi Electric Inverter Panel Operation Panelatribut:
- Applicable to: FR-E700, FR-F700PJ, FR-D700
- DV Kotak Panelatribut:
- Material: Steel
- Box Color: Grey (RAL 7032), Phospat Powder Coat
- Plate Colour: Orange (RAL 2000), Epoxy Polyester Powder Coat
- Product Content: Kunci Metal, Plat Loyang, Grounding Bolt, Engsel Flexible
- Protection Standard: IP65 & IK10
- MASKO Panel PlatDeskripsi:- Panel Box berkualitas- Panel box bahan dari plat besi- Tekstur permukaan box mirip kulit jeruk- Sudah termasuk dengan kunci pengaman box panelatribut:
- Index Protection: IP65
- Material: Plat Besi
- PANEL GRIDTECH Fuse Boxatribut:
- Dimensions (mm): 300x400x500
- Mitsubishi Electric Inverter Freqrol-D700 Series (Three-Phase 200V)atribut:
- Storage Temperature Range (°C): -20 to 65
- Mitsubishi Electric Small Terminal Cover For Earth Leakage/No-Fuse Circuit Breakeratribut:
- Color: White
- Mitsubishi Electric Inverter FREQROL-D700 Series 3 PhaseDeskripsi:High reliability and easy wiring have been achieved by the new standard spring clamp terminal (control circuit) of Mitsubishi inverter . Equipped with a safety stop function and a hardware cutoff circuit, highly reliable emergency output cutoff can be performed.Equipped with best-in-class performance ina compact body A compact body (3.7K or less) with the same mounting dimensions as Mitsubishi's smallest inverter FREQROL-S500 series is equipped with general-purpose magnetic flux vector control, 150% (3.7K or less) at 1Hz. Achieved high torque.Extensive functionsOptimal for fan / pump applications Excitation control / PID control, deceleration / stop function during power failure for machine tool applications, general-purpose magnetic flux vector control for transport / food applications, brake resistor connection (0.4K to 15K), etc. Equipped with various functions.Protective functionOvercurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overcurrent during acceleration, overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, fin overheating, input open phase, output side at start Ground fault overcurrent, output open phase, external thermal operation, PTC thermistor operation, parameter error, PU disconnection, retry count exceeded, CPU error, brake transistor error, inrush resistance overheat, analog input error, stall prevention, output current detection value exceeded , Safety circuit abnormality.Operation modeUpper and lower limit frequency setting, frequency jump operation, external thermal input selection, momentary power failure restart operation, forward / reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip correction, operation mode selection, offline auto tuning Function, PID control, computer link operation (RS-485), optimum excitation control, power failure stop, speed smoothing control, Modbus-RTUAlarm functionFan failure, overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake pre-alarm, electronic thermal pre-alarm, maintenance output, insufficient voltage, operation panel lock, password setting, inverter reset, safety stopatribut:
- Compatible Motor Capacity (kW): 5.5
- Output voltage (V): 3-phase 380-480
- Cooling Method: Forced air cooling
- Frequency (Hz): 50/60
- Power Supply Capacity (kVA): 12
- AC Voltage Tolerance (V): 325 to 528 (50/60Hz)
- Ambient Humidity (%RH): 90 or less (no condensation)
- Control Method: Soft-PWM control/High carrier frequency PWM control (selectable between V/F control, general-purpose magnetic flux vector control, and optimal excitation control)
- Length (mm): 155
- Output Frequency (Hz): 0.2 to 400
- Output Rated Current Standard (A): 12
- Output overload current rating: 150% 60s, 200% 0.5s (anti-time characteristic)
- Output rated capacity (kVA): 9.1
- Permissible Frequency Fluctuation (%): ±5
- Power Supply Voltage (V) : 3-phase 380-480 (50Hz/60Hz)
- Protective Structure: Closed type (IP20)
- Protective structure (JEM1030): Closed type (IP20)
- Storage Temperature (°C): -20 to 65
- Type: Simple and compact inverter (FREQROL-D700 series) Three-phase 400V
- Width (mm): 220
- NiGK Thermo Label(RU)3EDeskripsi:-Temperature can be detected by its color change.-Once discolored, the irreversible temperature material does not return to its original color. -Heat generation inspection of transformer/machineries.-Temperature control of heat treatment process.-Temperature control of distribution process.-Temperature control of power distribution equipment. -3 point display type-Indoor and outdoor use is possibleatribut:
- Primary Colors: White
- Element Size: phi5mm
- Measurement Precision: ±2°C
- Measuring Method: Irreversible
- Purpose of Use: Heat generation inspection of transformer/machineries. Temperature control of heat treatment process. Temperature control of distribution process. Temperature control of power distribution equipment.
- DV Automatic Transfer Switch PanelDeskripsi:Automatic Transfer Switch Panel. Best Quality, Affordable Price.atribut:
- Dimensions (cm): 50x40x20
- Phase: 3
- Current Rate (A): 63
- NiGK Thermo Label (RU) LIDeskripsi:-Once discolored, the irreversible temperature material does not return to its original color.-Heat generation inspection of transformer/machineries.-Temperature control of heat treatment process.-Indoor and outdoor use is possible
- Mitsubishi Electric Inverter Freqrol-D700 Series (3-Phase 400V)atribut:
- DC braking: Operating frequency (0 to 120Hz), operating time (0 to 10s), operating voltage (0 to 30%) variable
- Ambient Humidity (% RH): 90 or less (no condensation)
- AC voltage allowable fluctuation (V): 325 to 528
- Frequency Setting Resolution: Analog input 0.06Hz/60Hz (Terminals 2, 4:0 to 10V/10bit), 0.12Hz/60Hz (Terminals 2, 4:0 to 5V/9bit), 0.06Hz/60Hz (Terminals 4:0 to 20mA/10bit) Digital input 0.01Hz
- Output overload current rating: 150%60s, 200%0.5s (reverse time characteristic)
- Power Supply Voltage (V) : 3-phase 380 to 480 (50Hz/60Hz)
- Stall Prevention Operation Level: Operating current level can be set (0 to 200% variable), presence or absence can be selected
- Vibration (m/s²): 5.9
- Fort Box Panel Distribution Fiber Glass dengan Base Plate Bajaatribut:
- Material: Fiber Glass/SMC
- Temperature (°C): -40 to +120
- Protection : IP66
- Mitsubishi Electric Inverter Freqrol-D700 Series, Single-Phase 200Vatribut:
- Frequency Tolerance: ±5%
- Frequency (Hz): 50/60
- Type: Simple and compact inverter (FREQROL-D700 series) Single-phase 200V
- Ambient Humidity (% RH): 90 or less (no condensation)
- AC voltage allowable fluctuation (V): 170~264(50/60Hz)
- DC braking: Operating frequency (0 to 120Hz), operating time (0 to 10s), operating voltage (0 to 30%) variable
- Output Frequency (Hz): 0.2~400
- Output overload current rating: 150% 60s, 200% 0.5s (reverse time characteristic)
- Power Supply Voltage (V) : Single phase 200-240 (50Hz / 60Hz)
- Protective structure (JEM1030): Closed type (IP20)
- Type of control: Soft-PWM control / High carrier frequency PWM control (V / F control, general-purpose magnetic flux vector control, optimum excitation control can be selected)
- NETSUKEN Waterproof Digital ThermometerDeskripsi:Reliable waterproof structure The included SN3000-01 sensor is "protection class 7". Uses shock-absorbing rubber that is strong against drops . Power-saving design that can be used continuously for 2000 hours (about 3 months). The body is made of antibacterial resin, and the sensor probe is made of all stainless steel, which is hygienic. The response speed is fast and the frustration of the workplace is reduced. The temperature is grasped by the change of the resistance value. The operating temperature range is narrow (non-linear element)
- Uticon MCB Panel BoxDeskripsi:Kotak Panel MCB utk beberapa saklar pemutus MCB, Casing terbuat dari bahan polikarbonat yang tahan panas dan berdaya tahan tinggi, Terminal kontak kuningan, Instalasi kabel mudah dengan panel yang mudah dilepas dan terminal yang ditandai dengan jelas
- Chint MCB Box Panel Listrikatribut:
- Color: White
- Material: Plastic pure 100% ABS
- SIEMENS InverterDeskripsi:SINAMICS G120 Power Module PM230 unfiltered Degree of protection IP20 380-480 V 3 AC +10/-10% 47-63 Hz Power low overload: 18.5kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature 0 to +40 °C (LO) 355x 140x 165 (HxWxD), FSC without Control Unit and operating unit released for CU240B/E-2 and CU230P-2 Firmware version V4.4 or higher Note: PM230 supported no safety
- NiGK Corporation Thermo Label [[RU]] LIDeskripsi:-Once discolored, the irreversible temperature material does not return to its original color. -Heat generation inspection of transformer/machineries.-Temperature control of heat treatment process. -Indoor and outdoor use is possibleatribut:
- Primary Colors: White
- Element Size: phi11mm
- Sheet Size: 30x30mm
- Measurement Precision: ±2°C
- Measuring Method: Irreversible
Daftar Harga panel kontrol Terbaru September 2025
Mitsubishi Electric Inverter Panel Operation Panel | Rp359.900 |
DV Kotak Panel | Rp329.900 |
MASKO Panel Plat | Rp279.900 |
PANEL GRIDTECH Fuse Box | Rp9.999.900 |
Mitsubishi Electric Inverter Freqrol-D700 Series (Three-Phase 200V) | Rp2.299.900 |
Mitsubishi Electric Small Terminal Cover For Earth Leakage/No-Fuse Circuit Breaker | Rp19.000 |
Mitsubishi Electric Inverter FREQROL-D700 Series 3 Phase | Rp15.999.900 |
NiGK Thermo Label(RU)3E | Rp349.900 |
DV Automatic Transfer Switch Panel | Rp3.599.900 |
Mitsubishi Electric Parts For Fuseless Breaker Nf/Nv | Rp709.900 |
Data diperbarui pada 06/09/2025 (Harga belum termasuk PPN)